Time-integrated surface latent heat flux
Name: | time_integrated_surface_latent_heat_flux | Abbreviation: | slhf | Unit: | W m-2 s |
Definition | Exchange of latent heat (due to phase transitions: evaporation, condensation) with the surface through turbulent diffusion. |
Validity | accumulated from the beginning of the forecast |
Comment | The flux sign convention is positive downwards. The field will be archived once a day at 00Z. |
GRIB 2 | Discipline | = 0 | | | Parameter Category | = 0 | | | Parameter Number | = 10 | | | Type of statistical processing | = 1 | | | Type of first fixed surface | = 1 | Type of second fixed surface | = All 1's | Scale factor of first fixed surface | = All 1's | Scale factor of second fixed surface | = All 1's | Scaled value of first fixed surface | = All 1's | Scaled value of second fixed surface | = All 1's |
|
GRIB 2 and C-code for: Perturbed forecast, Control forecast, perturbed re-forecast and Control re-forecast |