The CAMS high resolution FC o-suite (experiment he9h running at tco1279, L137) was started on 2020-01-01, with an e-suite period from 2020-01-01 to 2020-10-31. Main new feature are:

Changes introduced during production affecting the quality of the products


 real dateexp datedescription of change
2021012520210122

The high resolution FC has been set to work on cyclic mode (using initial conditions from previous forecast) instead of being nudged with GHG analysis (hd7v). This is due to some technical problems with experiment hd7v that have delayed the experiment. The nudging of the initial conditions will be resumed once hd7v catches up in NRT.

2021020120210201The initial conditions for the high resolution FC have been set up to be nudged to hd7v after it caught up in NRT (4 days behind).



Technical changes introduced during production


 real dateexp datedescription of change
2021010720210101

Change FC length from T48 to T120







Flux updates



real dateexp datedescription of change
20201216202101012020 emissions used for CO2, CH4 and CO as new emissions for 2021 will not be delivered until March 2021


Changes in GHG observations



real dateexp datedescription of change




Changes introduced during e-suite phase




real dateexp datedescription of change

 

20200802Change the meteo initial conditions from hd7v (GHG esuite analysis) to NWP operational analysis (OD/0001 DA)

 

20200802–20200805Shift to using 4-day lagged GHG analysis from hd7v to allow near-real-time operation
Note: GHG fields retrieved for these dates on 6–7 August may have had a temporary problem and should be re-retreived.