You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
Version 1
Next »
Name: | soil_temperature | Abbreviation: | st | Unit: | K |
Definition | The average soil temperature on the top 20cm of the soil layer. |
Validity | instantaneous |
Comment | |
GRIB 2 | Discipline | = 2 | | | Parameter Category | = 0 | | | Parameter Number | = 2 | | | Type of first fixed surface | = 106 | Type of second fixed surface | = 106 | Scale factor of first fixed surface | = 0 | Scale factor of second fixed surface | = 1 | Scaled value of first fixed surface | = 0 | Scaled value of second fixed surface | = 2 |
|
GRIB 2 and C-code for: Deterministic forecast, Perturbed forecast and Control forecast |
Comments
Author | Contents | |
---|
Jörg Urban | ECMWFs has four soil layers: layer 1 from 0cm to 7cm, layer 2 from 7cm to 28cm, layer 3 from 28cm to 1m and layer 4 from 1m to 2.89m. The parameter soil temperature is then computed: st = ( 7 * T_1 + 13 * T_2 )/20, where T_i are the averaged soil temperatures on the i-th level. | |