...
Section | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
|
...
|
The Thermo View Editor
Type
Specifies the type of the Hovmøller Thermodynamic diagram to be produced. Options are:
Area Hovm - diagram derived from an input rectangular area.
Line Hovm - diagram derived from an input transect line
Vertical Hovm - diagram derived from an input rectangular area and a set of levels.
Line (Line Hovm)
The possible options are: tephigram, skewt, emagram. The default is tephigram.
Bottom Pressure
Specifies the value at the bottom of the pressure axis of the thermodynamic diagram.
Top Pressure
Specifies the value at the top of the pressure axis of the thermodynamic diagram.
Minimum Temperature
Specifies the minimum value on the temperature axis of the thermodynamic diagram.
Maximum Temperature
Specifies the maximum value on the temperature axis of the thermodynamic diagram.
Thermo Grid
Configures the background attributes of the thermodynamic diagram, please see Thermo Grid.
Point Selection
Specifies how the geographical location, for which the diagram is to be plotted, will be selected. Options are: Coordinates, Area Average and Station.
Coordinates
Specifies the geographical location for which the diagram is to be plottedSpecifies the coordinates of a transect line along which the Hovmøller diagram is calculated. Enter the coordinates (lat/long) of a line point separated by a "/" (lat1/long1/lat2/long2lat/long). Alternatively, use the coordinate assist button. Only available if Point Selection is Coordinates.
Area
...
Average
Specifies the coordinates of the a geographical area over which the Hovmøller diagram is calculatedan area average value will be used, instead of a point value, to produce the diagram. Enter the coordinates (lat/long) of an area separated by a "/" (top left lat and long, bottom right lat and long). Alternatively, use the coordinate assist button.
...
Only available if Point Selection is Area Average.
Station
Specifies the direction along location for which the averaging of the variable is performed. Options are North South and East West. For North South, the averaging is weighted by cos(latitude).
Date Min
Specifies the horizontal date minimum value. Default value AUTOMATIC indicates that the minimum value will be taken from the input data.
Date Max
Specifies the horizontal date maximum value. Default value AUTOMATIC indicates that the maximum value will be taken from the input data.
Bottom Level (Vertical Hovm)
Specifies the vertical lower limit value, as a pressure level (hPa) or model level (η levels).
Top Level (Vertical Hovm)
Specifies the vertical upper limit value, as a pressure level (hPa) or model level (η levels).
Swap Axes
By default, the definition of the vertical and horizontal axes of the Hovmøller diagrams follows pre-defined rules. However, if Swap Axes is set to Yes then the axes will be swapped around.
Resolution
Used to interpolate the data onto a regular grid, and applies to both the horizontal and vertical axes where appropriate. This parameter is essential for creating a Hovmøller diagram from satellite data.
Time Axis
Specifies the characteristics of the time-series axis to be used in the plotting of the data. Only an Axis Plotting icon can be dropped here. The following axis parameters are defined by the application; therefore, users should not change their values directly: Axis Type (set to Date), Axis Date Min Value and Axis Date Max Value (set according to the above parameters Date Min and Date Max, respectively), and Axis Orientation.
The Axis Orientation parameter is defined according to the following rules:
a) if the selected input pane is Line Hovm, the value is set to Horizontal;
b) if the selected input pane is Area Hovm and the Average Direction is East West, the value is set to Horizontal
c) if the selected input pane is Area Hovm and the Average Direction is North South, the value is set to Vertical.
d) if the selected input pane is Vertical Hovm, the value is set to Horizontal.
However, it is possible to change the Axis Orientation value from its calculated default by setting parameter Swap Axes to Yes. This option is not available for Vertical Hovm.
Geo Axis
Specifies the characteristics of the geographical axis to be used in the plotting of the data. Only an Axis Plotting icon can be dropped here. The following axis parameters are defined by the application; therefore, users should not change their values directly: Axis Min Value and Axis Max Value (set according to the values given by parameters Line or Area), Axis Type, Axis Tick Label Type and Axis Orientation. The Axis Type and Axis Tick Label Type parameters are defined according to the following rules:
a) if the selected input pane is Line Hovm, the Axis Type value is set to Geoline.
b) if the selected input pane is Area Hovm and the Average Direction is East West, the Axis Type value is set to Regular and Axis Tick Label Type to Latitude.
c) if the selected input pane is Area Hovm and the Average Direction is North South, the Axis Type value is set to Regular and Axis Tick Label Type to Longitude.
Moreover, the Axis Orientation parameter is defined according to the following rules:
a) if the selected input pane is Line Hovm, the value is set to Vertical
b) if the selected input pane is Area Hovm and the Average Direction is East West, the value is set to Vertical
c) if the selected input pane is Area Hovm and the Average Direction is North South, the value is set to Horizontal.
However, it is possible to change the Axis Orientation value from its calculated default by setting parameter Swap Axes to Yes.
Vertical Axis (Vertical Hovm)
Specifies the characteristics of the level-series axis to be used in the plotting of the data. Only an Axis Plotting icon can be dropped here. The following axis parameters are defined by the application; therefore, users should not change their values directly: Axis Min Value and Axis Max Value (set according to the input data set), Axis Type, Axis Tick Label Type and Axis Orientation.
Vertical Level Type (Vertical Hovm)
Specifies if a conversion from model level to pressure level needs to be performed. Options are As In Data and Pressure, If the conversion to pressure is selected and the input data is specified in model levels, the LNSP field should be added to the input data.
Vertical Scaling (Vertical Hovm)
diagram is to be plotted. A Stations icon should be dropped here. Only available if Point Selection is Station.
Point Extraction
Specifies the way to calculate values at the point location for GRIB thermodynamic diagrams. Options are:
Interpolate - interpolate values from the four surrounding grid points (default)
Nearest Gridpoint - use the data from the nearest grid point
Dew Point Formulation
Specifies the equation to compute the Dew Point parameter. Options are: Saturation Over Water and Mixed Phase 0 to -23.
Temperature Param
Specifies the parameter number of the temperature, if the data is a non-ECMWF. ECMWF uses specific parameter numbers different from the WMO ones.
Specific Humidity Param
Specifies the parameter number of the specific humidity, if the data is a non-ECMWF. ECMWF uses specific parameter numbers different from the WMO ones.
Lnsp Param
Specifies the parameter number of the Lnsp, if the data is a non-ECMWF. ECMWF uses specific parameter numbers different from the WMO ones.
U Wind Param
Specifies the parameter number of the U wind component, if the data is a non-ECMWF. ECMWF uses specific parameter numbers different from the WMO ones.
V Wind Param
Specifies the parameter number of the V wind component, if the data is a non-ECMWF. ECMWF uses specific parameter numbers different from the WMO ones.
Map Overlay Control
Specifies details of the overlaying of data units in the same plot. Options are Always (default), By Date, By Level, NeverSpecifies the type of vertical axis - Linear or Logarithmic.
Excerpt Include | ||||||
---|---|---|---|---|---|---|
|
...