The computation is based on the following formula:
Mathinlinemathdisplay |
---|
T_{v} = T (1 + \frac{1 - \epsilon}{\epsilon} q)
|
where
- T is the temperature
- q is the specific humidity
- ε = 0.621981
...
The computation is based on the following formula:
Mathinlinemathdisplay |
---|
T_{v} = T (1 + \frac{1 - \epsilon}{\epsilon} q)
|
where