This page has a list of known issues for the Cray compilers and compiler environment (all versions).
OpenIFS versions: 40r1 / 38r1
Panel | ||||
---|---|---|---|---|
| ||||
Fails in updclie with error: irregularly spaced fields |
Panel |
---|
This error occurs at the start of the model run. It has been found to be caused by specific version of the Cray compiler, cce/8.5.8 that comes with cdt/17.03. There have been reports that older versions may also give the same error. If this occurs, we recommend recompiling the model code with a more recent version. The model has been tested successfully with cdt versions 17.09, 18.04 and 18.07. If this is not possible, then recompiling the model with lower optimization, -O1, also fixesthe fixes the problem. To reduce the optimization, edit the file make/cfg/cce-opt.cfg, edit the line that begins |
Panel | ||||
---|---|---|---|---|
| ||||
Cray cce/8.5.8 compiler can cause failure in wave model |
Panel | ||||
---|---|---|---|---|
| ||||
The Cray fortran compiler version cce/8.5.8 can cause OpenIFS to fail. The error is seen on the first timestep in a call to Only cce/8.5.8 has this behaviour. We recommend using a more recent version if possible. To workaround the problem, please add an additional option to the compilation flags: 1. Edit the cray compiler configuration file in make/cfg/cce-opt.cfg (and the noopt, nansC versions) 2. Find the line:
3. Replace it with:
4. Recompile. If this does not solve the problem, please contact openifs-support@ecmwf.int for assistance. |
Panel | ||||
---|---|---|---|---|
| ||||
Cray ATP may not work |
Panel | ||
---|---|---|
| ||
Older versions of Cray ATP did not work with OpenIFS. This is caused by the way IFS creates its own signal handler. To enable Cray ATP set:
in the job script to completely disable any signal trapping by the IFS signal handler code 'DrHook'. Contact openifs-support@ecmwf.int for assistance. |
Panel | ||||
---|---|---|---|---|
| ||||
CrayPAT does not work |
Panel | ||
---|---|---|
| ||
This is a result of the way in which the OpenIFS is compiled. More information on this and the resolution is described here. |
HTML |
---|
<script type="text/javascript" src="https://softwarejira.ecmwf.int/issues/s/en_UKet2vtj/787/12/1.2.5/_/download/batch/com.atlassian.jira.collector.plugin.jira-issue-collector-plugin:issuecollector/com.atlassian.jira.collector.plugin.jira-issue-collector-plugin:issuecollector.js?collectorId=5fd84ec6"></script> |