Atmospheric model | HRES | ENS | ENS Extended |
---|
| Day 0 - 10 | Day 11 - 15 | Day 16 - 46 |
---|
| Current | Upgrade | Current | Upgrade | Current | Upgrade | Current | Upgrade |
---|
Spectral | TL1279 | TCO1279 | TL639 | TCO639 | TL319 | TCO639 | TL319 | TCO319 |
---|
Gaussian grid | N640 | O1280 | N320 | O640 | N160 | O640 | N160 | O320 |
---|
Horizontal grid resolution | ~16 km | ~9 km | ~32 km | ~18 km | ~64 km | ~18 km | ~64 km | ~36 km |
---|
Dissemination (LL) | 0.125° | 0.1° and 0.125° | 0.25° | 0.2° and 0.25° | 0.5° | 0.2° and 0.25° | 0.5° | 0.4° and 0.5° |
---|
Model Level Vertical resolution | 137 | 137 | 91 | 91 | 91 | 91 | 91 | 91 |
---|
- ENS day 11 - 15 will be run at the same resolution as ENS day 0 - 10.
- The current ENS overlap data provided from day 9 to 10 is discontinued.
- Overlap data is provided from day 14 to 15 for ENS Extended.
- The horizontal resolution of the ENS re-forecasts will be increased to match that of ENS.
- The two ENS constant-resolution forecasts provided for calibration and validation purposes are discontinued.
- There will be no change in the number and definition of the pressure levels.
- There will be no change in the model level vertical resolution.
Latitude-longitude resolutions for atmospheric products provided in disseminationHRES- HRES products will be available at the base grid resolution of 0.1° and multiples thereof.
- For backwards compatibility, HRES fields will also be available at the compatibility grid resolution of 0.125°.
- All product grids that can be generated from the base grid (0.1°) will be generated from that grid.
- Those grids that cannot be generated from the base grid will be generated with the compatibility grid (0.125°).
- For example, grids of 0.5° and 1.0° will be generated from the base grid; grids of 0.25° and 0.75° will be generated from the compatibility grid.
ENS- ENS products will be available at the base grid resolution of 0.2°and multiples thereof.
- For backwards compatibility, ENS products from will also be available at the compatibility grid resolution of 0.25° and multiples thereof.
- All product grids that can be generated from the base grid (0.2°) will be generated from that grid.
- Those grids that cannot be generated with the base grid will be generated with the compatibility grid (0.25°).
ENS Extended- ENS Extended products will be available at the base grid resolution of 0.4°and multiples thereof.
- For backwards compatibility, ENS Extended products from will also be available at the compatibility grid resolution of 0.5° and multiples thereof.
- All product grids that can be generated from the base grid (0.4°) will be generated from that grid.
- Those grids that cannot be generated with the base grid will be generated with the compatibility grid (0.5°).
|