To mirror the output resolution of the HRES and retrieve data at TCO1279, O1280 or 0.1° x 0.1° lat/long grid, the keywordsdata on the TCO7999 grid can be truncated and/or regridded. This is achieved using the following keywords:
'truncation' : '1279'
'grid' : 'O1280'
'grid' : '0.1/0.1'
can be used for spectral, or gridded data (respectively). This will improve the download time of the spectral data but reduce the resolution of the data.
Warning | ||
---|---|---|
| ||
Please note that data on the O8000 grid cannot currently be regridded and will cause the retrieval to fail. |
Output fields
Surface fields
...
The parameters on model levels (1 to 137; with model level 137 representing the lowest height), on the O8000 grid are as follows:
paramId | shortName | Name | units |
---|---|---|---|
75 | crwc | Specific rain water content | kg kg**-1 |
76 | cswc | Specific snow water content | kg kg**-1 |
133 | q | Specific humidity | kg kg**-1 |
246 | clwc | Specific cloud liquid water content | kg kg**-1 |
247 | ciwc | Specific cloud ice water content | kg kg**-1 |
248 | cc | Fraction of cloud cover | (0 - 1) |
The parameters on model levels (1 to 137; with model level 137 representing the lowest height), on the TCO7999 grid are as follows:
...
The parameters on pressure levels (1, 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 250, 300, 400, 500, 700, 850, 925, 1000), on the O8000 grid are as follows:
paramId | shortName | Name | units |
---|---|---|---|
60 | pv | Potential vorticity | K m**2 kg**-1 s**-1 |
133 | q | Specific humidity | kg kg**-1 |
The parameters on pressure levels (1, 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 250, 300, 400, 500, 700, 850, 925, 1000), on the TCO7999 grid are as follows:
...