path
: the path of the parcel. It is itself a definition with two members:t
andp
, each containing a list of values.area
: the positive and negative buoyancy areas between the parcel path and the profile. It is a list of definitions describing the areas.cape
: the value of the CAPE (Convective Available Potential Energy) (J/kg)cin:
value the CIN (Convective Inhibition) (J/kg)lcl
: the Lifted Condensation Level. It is a definition with two members:t
andp
. If no LCL exists it is set tonil
.lfc
: the Level of Free Convention. It is a definition with two members:t
andp
. If no LFC exists it is set tonil
.el
: the Equilibrium Level. It is a definition with two members:t
andp
. If no EL exists it is set tonil
.top
: the Cloud Top Level. It is a definition with two members:t
andp
. If no TOP exists it is set to nil.start
: the start conditions of the parcel with four members:mode
,t
,td
andp
.
...